:orphan: .. raw:: html .. dtcompatible:: nxp,s32-psi5 .. _dtbinding_nxp_s32_psi5: nxp,s32-psi5 ############ Vendor: :ref:`NXP Semiconductors N.V. ` .. note:: An implementation of a driver matching this compatible is available in :zephyr_file:`drivers/psi5/psi5_nxp_s32.c`. Description *********** .. code-block:: none NXP S32 PSI5 (Peripheral Sensor Interface) Controller Properties ********** Top level properties ==================== These property descriptions apply to "nxp,s32-psi5" nodes themselves. This page also describes child node properties in the following sections. .. tabs:: .. group-tab:: Node specific properties Properties not inherited from the base binding file. .. list-table:: :widths: 1 1 4 :header-rows: 1 * - Name - Type - Details * - ``pinctrl-0`` - ``phandles`` - .. code-block:: none Pin configuration/s for the first state. Content is specific to the selected pin controller driver implementation. This property is **required**. * - ``pinctrl-names`` - ``string-array`` - .. code-block:: none Names for the provided states. The number of names needs to match the number of states. This property is **required**. * - ``pinctrl-1`` - ``phandles`` - .. code-block:: none Pin configuration/s for the second state. See pinctrl-0. * - ``pinctrl-2`` - ``phandles`` - .. code-block:: none Pin configuration/s for the third state. See pinctrl-0. * - ``pinctrl-3`` - ``phandles`` - .. code-block:: none Pin configuration/s for the fourth state. See pinctrl-0. * - ``pinctrl-4`` - ``phandles`` - .. code-block:: none Pin configuration/s for the fifth state. See pinctrl-0. .. group-tab:: Deprecated node specific properties Deprecated properties not inherited from the base binding file. (None) .. group-tab:: Base properties Properties inherited from the base binding file, which defines common properties that may be set on many nodes. Not all of these may apply to the "nxp,s32-psi5" compatible. .. list-table:: :widths: 1 1 4 :header-rows: 1 * - Name - Type - Details * - ``reg`` - ``array`` - .. code-block:: none Information used to address the device. The value is specific to the device (i.e. is different depending on the compatible property). The "reg" property is typically a sequence of (address, length) pairs. Each pair is called a "register block". Values are conventionally written in hex. For details, see "2.3.6 reg" in Devicetree Specification v0.4. This property is **required**. See :ref:`zephyr:dt-important-props` for more information. * - ``status`` - ``string`` - .. code-block:: none Indicates the operational status of the hardware or other resource that the node represents. In particular: - "okay" means the resource is operational and, for example, can be used by device drivers - "disabled" means the resource is not operational and the system should treat it as if it is not present For details, see "2.3.4 status" in Devicetree Specification v0.4. Legal values: ``'ok'``, ``'okay'``, ``'disabled'``, ``'reserved'``, ``'fail'``, ``'fail-sss'`` See :ref:`zephyr:dt-important-props` for more information. * - ``compatible`` - ``string-array`` - .. code-block:: none This property is a list of strings that essentially define what type of hardware or other resource this devicetree node represents. Each device driver checks for specific compatible property values to find the devicetree nodes that represent resources that the driver should manage. The recommended format is "vendor,device", The "vendor" part is an abbreviated name of the vendor. The "device" is usually from the datasheet. The compatible property can have multiple values, ordered from most- to least-specific. Having additional values is useful when the device is a specific instance of a more general family, to allow the system to match the most specific driver available. For details, see "2.3.1 compatible" in Devicetree Specification v0.4. This property is **required**. See :ref:`zephyr:dt-important-props` for more information. * - ``reg-names`` - ``string-array`` - .. code-block:: none Optional names given to each register block in the "reg" property. For example: / { soc { #address-cells = <1>; #size-cells = <1>; uart@1000 { reg = <0x1000 0x2000>, <0x3000 0x4000>; reg-names = "foo", "bar"; }; }; }; The uart@1000 node has two register blocks: - one with base address 0x1000, size 0x2000, and name "foo" - another with base address 0x3000, size 0x4000, and name "bar" * - ``interrupts`` - ``array`` - .. code-block:: none Information about interrupts generated by the device, encoded as an array of one or more interrupt specifiers. The format of the data in this property varies by where the device appears in the interrupt tree. Devices with the same "interrupt-parent" will use the same format in their interrupts properties. For details, see "2.4 Interrupts and Interrupt Mapping" in Devicetree Specification v0.4. See :ref:`zephyr:dt-important-props` for more information. * - ``interrupts-extended`` - ``compound`` - .. code-block:: none Extended interrupt specifier for device, used as an alternative to the "interrupts" property. For details, see "2.4 Interrupts and Interrupt Mapping" in Devicetree Specification v0.4. * - ``interrupt-names`` - ``string-array`` - .. code-block:: none Optional names given to each interrupt generated by a device. The interrupts themselves are defined in either "interrupts" or "interrupts-extended" properties. For details, see "2.4 Interrupts and Interrupt Mapping" in Devicetree Specification v0.4. * - ``interrupt-parent`` - ``phandle`` - .. code-block:: none If present, this refers to the node which handles interrupts generated by this device. For details, see "2.4 Interrupts and Interrupt Mapping" in Devicetree Specification v0.4. * - ``label`` - ``string`` - .. code-block:: none Human readable string describing the device. Use of this property is deprecated except as needed on a case-by-case basis. For details, see "4.1.2 Miscellaneous Properties" in Devicetree Specification v0.4. See :ref:`zephyr:dt-important-props` for more information. * - ``clocks`` - ``phandle-array`` - .. code-block:: none Information about the device's clock providers. In general, this property should follow conventions established in the dt-schema binding: https://github.com/devicetree-org/dt-schema/blob/main/dtschema/schemas/clock/clock.yaml * - ``clock-names`` - ``string-array`` - .. code-block:: none Optional names given to each clock provider in the "clocks" property. * - ``#address-cells`` - ``int`` - .. code-block:: none This property encodes the number of cells used by address fields in "reg" properties in this node's children. For details, see "2.3.5 #address-cells and #size-cells" in Devicetree Specification v0.4. * - ``#size-cells`` - ``int`` - .. code-block:: none This property encodes the number of cells used by size fields in "reg" properties in this node's children. For details, see "2.3.5 #address-cells and #size-cells" in Devicetree Specification v0.4. * - ``dmas`` - ``phandle-array`` - .. code-block:: none DMA channel specifiers relevant to the device. * - ``dma-names`` - ``string-array`` - .. code-block:: none Optional names given to the DMA channel specifiers in the "dmas" property. * - ``io-channels`` - ``phandle-array`` - .. code-block:: none IO channel specifiers relevant to the device. * - ``io-channel-names`` - ``string-array`` - .. code-block:: none Optional names given to the IO channel specifiers in the "io-channels" property. * - ``mboxes`` - ``phandle-array`` - .. code-block:: none Mailbox / IPM channel specifiers relevant to the device. * - ``mbox-names`` - ``string-array`` - .. code-block:: none Optional names given to the mbox specifiers in the "mboxes" property. * - ``power-domains`` - ``phandle-array`` - .. code-block:: none Power domain specifiers relevant to the device. * - ``power-domain-names`` - ``string-array`` - .. code-block:: none Optional names given to the power domain specifiers in the "power-domains" property. * - ``#power-domain-cells`` - ``int`` - .. code-block:: none Number of cells in power-domains property * - ``zephyr,deferred-init`` - ``boolean`` - .. code-block:: none Do not initialize device automatically on boot. Device should be manually initialized using device_init(). * - ``wakeup-source`` - ``boolean`` - .. code-block:: none Property to identify that a device can be used as wake up source. When this property is provided a specific flag is set into the device that tells the system that the device is capable of wake up the system. Wake up capable devices are disabled (interruptions will not wake up the system) by default but they can be enabled at runtime if necessary. * - ``zephyr,pm-device-runtime-auto`` - ``boolean`` - .. code-block:: none Automatically configure the device for runtime power management after the init function runs. * - ``zephyr,disabling-power-states`` - ``phandles`` - .. code-block:: none List of power states that will disable this device power. Child node properties ===================== .. list-table:: :widths: 1 1 4 :header-rows: 1 * - Name - Type - Details * - ``interrupts`` - ``array`` - .. code-block:: none Information about the channel interrupts. This property is **required**. See :ref:`zephyr:dt-important-props` for more information. * - ``num-rx-buf`` - ``int`` - .. code-block:: none Specifies the maximum number of receive buffers used for storing PSI5 messages. The value can range from 1 to 32, determining how many messages can be stored in the buffer at any given time. This property is **required**. * - ``reg`` - ``int`` - .. code-block:: none Channel identifier. This property is **required**. See :ref:`zephyr:dt-important-props` for more information. * - ``async-mode`` - ``boolean`` - .. code-block:: none Determines the channel operation mode. When set to true, the channel operates in asynchronous mode with only the receive function active. When set to false, the channel operates in synchronous mode with both transmit and receive functions active. * - ``period-sync-pulse-us`` - ``int`` - .. code-block:: none Specifies the period of the internally generated synchronization pulses, measured in microseconds (us). This value determines the length of each synchronization pulse used in the system. * - ``pulse-width-0-us`` - ``int`` - .. code-block:: none Specifies the duration of the pulse width for a data bit value '0', measured in microseconds (us). * - ``pulse-width-1-us`` - ``int`` - .. code-block:: none Specifies the duration of the pulse width for a data bit value '1', measured in microseconds (us). * - ``decoder-start-offset-us`` - ``int`` - .. code-block:: none Specifies the duration for which the Manchester decoder remains inactive after the falling edge of a synchronization pulse, measured in microseconds (us). This value determines the delay before the decoder starts processing incoming signals again. * - ``tx-frame`` - ``string`` - .. code-block:: none Specifies the transmitter mode. Each mode defines the frame length and the start condition for data transmission: - short-31-1s: Short Frame (V1.3) with at least 31 consecutive '1' bits as the start condition - short-5-0s: Short Frame (V1.3) with at least 5 consecutive '0' bits as the start condition - long-31-1s: Long Frame (V1.3) with at least 31 consecutive '1' bits as the start condition - long-5-0s: Long Frame (V1.3) with at least 5 consecutive '0' bits as the start condition - x-long-31-1s: X-Long Frame (V1.3) with at least 31 consecutive '1' bits as the start condition - x-long-5-0s: X-Long Frame (V1.3) with at least 5 consecutive '0' bits as the start condition - xx-long: XX-Long (V2.0) - non-standard: Non Standard Length Legal values: ``'short-31-1s'``, ``'short-5-0s'``, ``'long-31-1s'``, ``'long-5-0s'``, ``'x-long-31-1s'``, ``'x-long-frame-5-0s'``, ``'xx-long-frame'``, ``'non-standard-frame'`` * - ``rx-bitrate-kbps`` - ``int`` - .. code-block:: none Selects the receive message bitrate in kbps. This setting determines the speed at which data is received. This property is **required**. Legal values: ``125``, ``189`` Grandchild node properties ========================== .. list-table:: :widths: 1 1 4 :header-rows: 1 * - Name - Type - Details * - ``reg`` - ``int`` - .. code-block:: none Channel RX slot identifier. This property is **required**. See :ref:`zephyr:dt-important-props` for more information. * - ``duration-us`` - ``int`` - .. code-block:: none Specifies the duration of a slot, starting from the rising edge of the timing synchronization pulse and ending at the final slot. This property is **required**. * - ``start-offset-us`` - ``int`` - .. code-block:: none Specifies the time offset at which the slot should start, measured from the rising edge of the timing synchronization pulse. This property is **required**. * - ``data-length`` - ``int`` - .. code-block:: none Specifies the number of bits in a slot, with valid lengths ranging from 8 to 28 bits. This property is **required**. * - ``data-msb-first`` - ``boolean`` - .. code-block:: none Specifies the endianness type for data slot. Set to 1 when data is interpreted with the Most Significant Bit (MSB) first. * - ``has-smc`` - ``boolean`` - .. code-block:: none Specifies whether data slot has Serial Messaging Channel (SMC) field. Set to 1 when the bit (M0, M1) SMC is present in the Rx Message. * - ``has-parity`` - ``boolean`` - .. code-block:: none Specifies whether data slot has parity field. Set to 1 when the Parity field is present in the Rx Message; otherwise, the CRC field is present.