st,stm32h7rs-pll-clock
Vendor: STMicroelectronics N.V.
Description
PLL node binding for STM32H7RS devices
It can be used to describe 3 different PLLs: PLL1 (Main PLL), PLL2 and PLL3.
These PLLs could take one of clk_hse, clk_hsi or clk_csi as input clock, with
an input frequency from 1 to 16 MHz. PLLM factor is used to set the input
clock in this acceptable range.
Each PLL can have up to 5 output clocks and for each output clock, the
frequency can be computed with the following formulae:
f(PLL_Px) = f(VCOx clock) / PLLPx -> pllx_p_ck ((pll1_p_ck : sys_ck))
f(PLL_Qx) = f(VCOx clock) / PLLQx -> pllx_q_ck
f(PLL_Rx) = f(VCOx clock) / PLLRx -> pllx_r_ck
f(PLL_Sx) = f(VCOx clock) / PLLSx -> pllx_s_ck
f(PLL_Tx) = f(VCOx clock) / PLLTx -> pllx_t_ck (only for PLL2)
with f(VCOx clock) = f(REFx_CK) × (PLLNx / PLLMx)
Properties
Properties not inherited from the base binding file.
Name |
Type |
Details |
---|---|---|
|
|
Number of items to expect in a Clock specifier
This property is required. |
|
|
Division factor for PLLx
input clock
Valid range: 1 - 63
This property is required. |
|
|
Main PLL multiplication factor for VCOx
Valid range: 4 - 512
This property is required. |
|
|
PLL division factor for pllx_p_ck
Valid range: 1 - 128
|
|
|
PLL division factor for pllx_q_ck
Valid range: 1 - 128
|
|
|
PLL division factor for pllx_r_ck
Valid range: 1 - 128
|
|
|
PLL division factor for pllx_s_ck : valid for PLL1, 2, 3
Valid range: 1 - 8
|
|
|
PLL division factor for pllx_t_ck : valid for PLL2
Valid range: 1 - 8
|
Deprecated properties not inherited from the base binding file.
(None)
Properties inherited from the base binding file, which defines common properties that may be set on many nodes. Not all of these may apply to the “st,stm32h7rs-pll-clock” compatible.
Name |
Type |
Details |
---|---|---|
|
|
Property to identify that a device can be used as wake up source.
When this property is provided a specific flag is set into the
device that tells the system that the device is capable of
wake up the system.
Wake up capable devices are disabled (interruptions will not wake up
the system) by default but they can be enabled at runtime if necessary.
|
|
|
Power domain the device belongs to.
The device will be notified when the power domain it belongs to is either
suspended or resumed.
|
|
|
Automatically configure the device for runtime power management after the
init function runs.
|
|
|
List of power states that will disable this device power.
|
|
|
indicates the operational status of a device
Legal values: See Important properties for more information. |
|
|
compatible strings
This property is required. See Important properties for more information. |
|
|
register space
See Important properties for more information. |
|
|
name of each register space
|
|
|
interrupts for device
See Important properties for more information. |
|
|
extended interrupt specifier for device
|
|
|
name of each interrupt
|
|
|
phandle to interrupt controller node
|
|
|
Human readable string describing the device (used as device_get_binding() argument)
See Important properties for more information. This property is deprecated. |
|
|
Clock gate information
This property is required. |
|
|
name of each clock
|
|
|
number of address cells in reg property
|
|
|
number of size cells in reg property
|
|
|
DMA channels specifiers
|
|
|
Provided names of DMA channel specifiers
|
|
|
IO channels specifiers
|
|
|
Provided names of IO channel specifiers
|
|
|
mailbox / IPM channels specifiers
|
|
|
Provided names of mailbox / IPM channel specifiers
|
|
|
Do not initialize device automatically on boot. Device should be manually
initialized using device_init().
|