Precision Time Protocol (PTP)

Overview

PTP is a network protocol implemented in the application layer, used to synchronize clocks in a computer network. It’s accurate up to less than a microsecond. The stack supports the protocol and procedures as defined in the IEEE 1588-2019 standard (IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems). It has multiple profiles, and can be implemented on top of L2 (Ethernet) or L3 (UDP/IPv4 or UDP/IPv6). Its accuracy is achieved by using hardware timestamping of the protocol packets.

Zephyr’s implementation of PTP stack consist following items:

  • PTP stack thread that handles incoming messages and events

  • Integration with ptp_clock driver

  • PTP stack initialization executed during system init

The implementation automatically creates PTP Ports (each PTP Port corresponds to unique interface).

Supported features

Implementation of the stack doesn’t support all features specified in the standard. In the table below all supported features are listed.

Supported features

Feature

Supported

Ordinary Clock

yes

Boundary Clock

yes

Transparent Clock

Management Node

End to end delay mechanism

yes

Peer to peer delay mechanism

Multicast operation mode

Hybrid operation mode

Unicast operation mode

Non-volatile storage

UDP IPv4 transport protocol

yes

UDP IPv6 transport protocol

yes

IEEE 802.3 (Ethernet) transport protocol

Hardware timestamping

yes

Software timestamping

TIME_RECEIVER_ONLY PTP Instance

yes

TIME_TRANSMITTER_ONLY PTP Instance

Supported Management messages

Based on Table 59 from section 15.5.2.3 of the IEEE 1588-2019 following management TLVs are supported:

Supported management message’s IDs

Management_ID

Management_ID name

Allowed actions

0x0000

NULL_PTP_MANAGEMENT

GET SET COMMAND

0x0001

CLOCK_DESCRIPTION

GET

0x0002

USER_DESCRIPTION

GET

0x0003

SAVE_IN_NON_VOLATILE_STORAGE

0x0004

RESET_NON_VOLATILE_STORAGE

0x0005

INITIALIZE

0x0006

FAULT_LOG

0x0007

FAULT_LOG_RESET

0x2000

DEFAULT_DATA_SET

GET

0x2001

CURRENT_DATA_SET

GET

0x2002

PARENT_DATA_SET

GET

0x2003

TIME_PROPERTIES_DATA_SET

GET

0x2004

PORT_DATA_SET

GET

0x2005

PRIORITY1

GET SET

0x2006

PRIORITY2

GET SET

0x2007

DOMAIN

GET SET

0x2008

TIME_RECEIVER_ONLY

GET SET

0x2009

LOG_ANNOUNCE_INTERVAL

GET SET

0x200A

ANNOUNCE_RECEIPT_TIMEOUT

GET SET

0x200B

LOG_SYNC_INTERVAL

GET SET

0x200C

VERSION_NUMBER

GET SET

0x200D

ENABLE_PORT

COMMAND

0x200E

DISABLE_PORT

COMMAND

0x200F

TIME

GET SET

0x2010

CLOCK_ACCURACY

GET SET

0x2011

UTC_PROPERTIES

GET SET

0x2012

TRACEBILITY_PROPERTIES

GET SET

0x2013

TIMESCALE_PROPERTIES

GET SET

0x2014

UNICAST_NEGOTIATION_ENABLE

0x2015

PATH_TRACE_LIST

0x2016

PATH_TRACE_ENABLE

0x2017

GRANDMASTER_CLUSTER_TABLE

0x2018

UNICAST_TIME_TRANSMITTER_TABLE

0x2019

UNICAST_TIME_TRANSMITTER_MAX_TABLE_SIZE

0x201A

ACCEPTABLE_TIME_TRANSMITTER_TABLE

0x201B

ACCEPTABLE_TIME_TRANSMITTER_TABLE_ENABLED

0x201C

ACCEPTABLE_TIME_TRANSMITTER_MAX_TABLE_SIZE

0x201D

ALTERNATE_TIME_TRANSMITTER

0x201E

ALTERNATE_TIME_OFFSET_ENABLE

0x201F

ALTERNATE_TIME_OFFSET_NAME

0x2020

ALTERNATE_TIME_OFFSET_MAX_KEY

0x2021

ALTERNATE_TIME_OFFSET_PROPERTIES

0x3000

EXTERNAL_PORT_CONFIGURATION_ENABLED

0x3001

TIME_TRANSMITTER_ONLY

0x3002

HOLDOVER_UPGRADE_ENABLE

0x3003

EXT_PORT_CONFIG_PORT_DATA_SET

0x4000

TRANSPARENT_CLOCK_DEFAULT_DATA_SET

0x4001

TRANSPARENT_CLOCK_PORT_DATA_SET

0x4002

PRIMARY_DOMAIN

0x6000

DELAY_MECHANISM

GET

0x6001

LOG_MIN_PDELAY_REQ_INTERVAL

GET SET

Enabling the stack

The following configuration option must me enabled in prj.conf file.

Testing

The stack has been informally tested using the Linux ptp4l daemons. The PTP sample application from the Zephyr source distribution can be used for testing.

API Reference

group ptp

Precision Time Protocol (PTP) support.

Defines

PTP_MAJOR_VERSION

Major PTP Version.

PTP_MINOR_VERSION

Minor PTP Version.

PTP_VERSION

PTP version IEEE-1588:2019.