CONFIG_WDT_ITE_WARNING_LEADING_TIME_MS¶
Number of ms before generating watchdog event/signal
Type: int
Help¶
This option defines the window in which a watchdog event must be
handled. After this time window, the watchdog reset triggers
immediately.
Default¶
- 500 
Kconfig definition¶
At <Zephyr Driver>/watchdog/Kconfig.it8xxx2:13
Included via Kconfig:8 → Kconfig.zephyr:42 → <Zephyr Driver>/Kconfig:54 → <Zephyr Driver>/watchdog/Kconfig:59
Menu path: (Top) → Device Drivers → Watchdog Support
config WDT_ITE_WARNING_LEADING_TIME_MS
    int "Number of ms before generating watchdog event/signal"
    default 500
    depends on WATCHDOG
    help
      This option defines the window in which a watchdog event must be
      handled. After this time window, the watchdog reset triggers
      immediately.