TI_TMP11X Sample
Description
This sample application periodically takes temperature readings using the ti_tmp11x sensor driver. The result is written to the console. This sample also included the code to use the features provided by TMP117 and TMP119, which are sensors similar to TMP116.
Requirements
This sample needs a TI TMP116, TI TMP117 or TI TMP119 sensor connected to the target board’s I2C connector.
Wiring
This sample is tested with Nucleo STM32F401RE board.
The sensor operates at 3.3V and uses I2C to communicate with the board.
External Wires:
Breakout GND pin <–> Nucleo GND pin
Breakout VCC pin <–> Nucleo 3V3 pin
Breakout SDA pin <–> Nucleo CN5-D14 pin
Breakout SCL pin <–> Nucleo CN5-D15 pin
Building and Running
In order to build the sample, connect the board to the computer with a USB cable and enter the following commands:
west build -b nucleo_f401re samples/sensor/tmp11x
west flash
Sample Output
The output can be seen via a terminal emulator (e.g. minicom). Connect the board with a USB cable to the computer and open /dev/ttyACM0 with the below serial settings:
Baudrate: 115200
Parity: None
Data: 8
Stop bits: 1
The output should look like this:
Device TMP11X - 0x200010a8 is ready
temp is 26.7031250 oC
temp is 26.7109375 oC
...